BOOCCA averaging pitot tube flow sensors, based on differential pressure principle with insertion mounting way, combine with DP transmitters to measure mass flow rate and volume flow rate. For a long time, they have been widely used in metallurgy, petrochemical and electric power industries with its high precision,long-term stability, low head loss, less cost in installation and sequent operation and maintenance.
Measuring Blast Furnace Gas
The blast furnace gas is usually dirty, and the pressure is also low. Measuring it with our WF10-200S flow sensor, the pressure loss is quite small. On-line installation and maintenance are available. |
Measuring Flue Gas In large pipeline
Using one or more WF10-500 flow sensors for a combination to measure flue gas, not only improves the measuring accuracy greatly when the straight pipe is inadequate, but also makes the cost low and installation easy. |
Measuring Nitrogen Gas
Adopting WF10-050 accelerating flow sensor whose turndown can reach 65:1 can solve the problem that it is hard to measure when the turndown needed is wide or the flow rate is very low. Furthermore, the pressure loss nearly approaches zero and it will reduce the cost in installation, sequent operation and maintenance greatly. |